45° flammability tester evaluates textile burn damage and melt resistance.
E-Mail-Adresse: info@standard-groups.com
A method is used to determine the damaged area and the length of the damage when the textiles and other materials are burned at 45 °, and the B method is used to determine the number of times the textile contacts the flame at a 45 ° state with hot melt to a specified length.
Standards
GB/T 14645-2014 Textiles-Burning behaviour-45°test determination of damaged area and ignition times
Technical Parameters
Items | Parameters |
Afterflame time range | 0~99.99s, resolution:0.01s |
Afterglow time range | 0 ~ 99.99s, resolution: 0.01s Ignition tip distance from the sample distance |
Ignition time | A method: thin fabric 30s; thick fabric 120s B method: manual |
Igniter caliber | A method: thin fabric Φ6.4mm; thick fabric Φ20mm B method: Φ6.4mm |
Sample clip size | A method: shape 500mm × 230mm; inner frame 250mm × 150mm B method: spiral diameter Φ10mm; pitch 2mm; total length 150mm |
Igniter top distance from the sample | A method: thin fabric 45mm; thick fabric 65mm B method : 45mm |
Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.