Features and Benefits1.Efficient cooling and heating systems, rapid cooling and heating can be
WhatsApp: +86 13816217984
E-Mail :info@qinsun-lab.com
1.Efficient cooling and heating systems, rapid cooling and heating can be achieved, shortening the test cycle. The heating rate of some advanced test chambers can reach 3℃/min or more, and the cooling rate can reach 1℃/min.
2. Temperature control accuracy can reach ±0.5℃, humidity control accuracy maintain at ±2.5%RH, temperature and humidity control range is wide, can test the product in extreme hot and cold, dry or high humidity environment.
3. Solid structure, refrigeration, heating, humidification and other key system performance is stable, can be long-term stable operation, to ensure the continuity and stability of the test process, for product durability testing, etc.
4. Equipped with observation window, convenient observation of sample status. The left side of the workroom is equipped with a test interface, which can test the electrical properties and other aspects of the sample.
Modell | STD TH-100 | STD TH-225 | STD TH-500 | STD TH-1000 |
Internal Dimension (mm) | 400*500*500 | 500*600*750 | 700*800*900 | 1000*1000*1000 |
Overall Dimension (mm) | 900*1050*1620 | 1000*1140*1870 | 1200*1340*2020 | 1500*1540*2140 |
Interior Volume | 100L | 225L | 500L | 1000L |
Heat load | 1000W | |||
Temperature Range | A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ | |||
Temperature Fluctuation | ± 0.5 ℃ | |||
Temperature Deviation | ± 2.0 ℃ | |||
Humidity Range | 20% ~ 98% RH | |||
Humidity Deviation | ± 2.5% RH | |||
Cooling Rate | 1 ℃ / min | |||
Heating Rate | 3 ℃ / min |
Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.