Detailed Product DescriptionApplicable Standard:SH/T0059;ASTM D5800Temperature Control Mode:Dig
WhatsApp: +86 13816217984
E-Mail :info@qinsun-lab.com
Applicable Standard: | SH/T0059;ASTM D5800 | Temperature Control Mode: | Digital Display PID Temperature Control |
---|---|---|---|
Temperature Control Range: | Room Temperature ~ 250 ± 0.1 ℃, Precision 0.01 ℃ | Heating Mode: | Metal Bath Heating |
Pressure Regulation: | High Precision Needle Valve | Suction Method: | Vacuum Pump |
Differential Pressure Meter: | Imported Precision Slant Tube Differential Pressure Meter | ||
Highlight: | Noack Method Evaporation Loss Analyzer Lubricating Oil Evaporation Loss Tester ASTM D5800 Evaporation Loss Analyzer |
This instrument is designed and manufactured as per procedure A of SH/T 0059 and procedure A of ASTM D5800 Standard Method for Evaporation Loss of Lubricating Oils by the Noack Method.
It is used to determine the evaporation loss of lubricating oils (particularly engine oils). The evaporation measured is reported as percent total loss.
1. The instrument should be placed on a fixed and flat workbench. Cross-ventilation should be avoided as far as possible in the environment.
2. No naked fire is allowed around the instrument during operation because of inflammable materials.
3. The instrument should be placed in the dry and ventilated environment.
4. The power supply should be single-phase and three-wire. The instrument must be grounded well.
Technical Features
This instrument is mainly composed of a heating bath and a filtering unit. It has below features:
1. Metal-blocked heating bath. Safe and environmental.
2. Wood-metal is used to provide good heating performance.
3. Specialized vacuum filtering system is equipped.
4. A digital timer is equipped for recording the test time.
5. International brand needle valve and precise pressure regulation system makes the flow correct.
6. Colored touch LCD operation. Easy to use.
Applicable standard | SH/T0059 |
Temperature control mode | digital display PID temperature control |
Temperature control range | room temperature ~ 250 ± 0.1 ℃, precision 0.01 ℃ |
Heating mode | metal bath heating |
Pressure regulation | high precision needle valve |
Suction method | vacuum pump |
Differential pressure meter | imported precision slant tube differential pressure meter |
Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.
Unternehmen Telefon
+86-21-6420 0566
Arbeitszeiten
Montag bis Freitag
Handy:
13816217984
Email:
info@qinsun-lab.com