Detailed Product DescriptionWavenumber Scanning Range:3400cm-1~2400cm-1 WavenumberRepeatability

WhatsApp: +86 13816217984

E-Mail :info@qinsun-lab.com

Inhalt

Detailed Product Description

Wavenumber Scanning Range:3400cm-1~2400cm-1 WavenumberRepeatability:±1cm-1 Wavenumber
Accuracy:±1cm-1Spectrum Resolution:1 Cm-1
Absorbance Linear Range:0.0000~1.9999Correlation Coefficient:R>0.999 ( Infrared Non-dispersive Method)
Basic Measurement Range:0.02~800mg/LDetection Concentration:80000mg/L (dilution Measurement)
Highlight:

Infrared Photometric Oil Meter

Infrared Photometric Oil Measuring Instrument

Product Description

The infrared photometric oil measuring instrument is a high-precision analytical instrument, which adopts an integrated optical path system with reasonable optical path design, strong signal and high signal-to-noise ratio. Aluminum alloy casting base, after natural failure treatment, external power supply, injection molded shell, beautiful and generous, light in size and weight, it can be used as a portable instrument as well as a laboratory instrument.

Technical Features

Switching power supply, wide power supply range, automatic switching mechanism between samples and reference cells, positioning, eliminating errors, and making the influence of mechanical errors approach zero cosecant mode for wave number positioning and scanning, so that the wave number positioning accuracy is less than one wave number and three wave numbers, in line with "HJ 637” does not need to make a standard curve, only a set of calibration coefficients is used to simulate the oil composition in water, and the error of measuring the standard oil of any component is less than 5%, so that the instrument is equipped with a meal fume measurement menu for the actual water sample service, completely according to the diet Oil fume emission standard GB18483 measurement of oil fume in catering industry.

Chinese menu operation, equipped with a large-screen LCD display , no need for calibration of standard samples, measurement results can be printed out, can be used independently from the computer , can be connected to a computer system for operation, the wave number can be freely compensated and positioned , and can be quantitatively measured, Qualitative analysis is also possible; the spectrum is clear and various interfering substances can be distinguished.

Technical Parameters

Wavenumber scanning range3400cm-1~2400cm-1 Wavenumber
repeatability±1cm-1 Wavenumber
accuracy±1cm-1
Spectrum resolution1 cm-1
Absorbance linear range0.0000~1.9999
Correlation coefficientr>0.999 ( Infrared non-dispersive method)
Basic measurement range0.02~800mg/L
Detection concentration0.0001mg/L
Detection concentration80000mg/L (dilution measurement)
Detection limit 3SD<0.2mg/L
Baseline drift<1% /4h
Measurement error of different proportions<5% (mixed hydrocarbons in different proportions to simulate actual water samples)
Power supply220V±10V 50HZ±1HZ
Humidity<80%
Temperature5~35°C
Dimensions500×250×150 (mm)
Weight5.5kg


Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.