Product DetailsFor tufted carpets or traditional carpets, an important parameter is the retention pe
E-Mail-Adresse: info@standard-groups.com
Product Details
For tufted carpets or traditional carpets, an important parameter is the retention performance of their tufts.
Poor - quality carpets may completely lose their tufts in certain situations, such as on staircases. For loop - pile carpets, well - formed loops can prevent the formation of long loops. This instrument can measure the force required to pull out a single tuft or loop from the carpet, that is, the bonding force between the carpet pile and the backing. This instrument is commonly used for testing small quantities of samples in laboratories, but it can also be applied in specific scenarios involving existing carpets or large - scale carpets.
Test Method
The carpet sample is fixed by a steel template. Hold one end of the tuft to be tested with a pair of surgical forceps, or hook a loop with a metal hook. The surgical forceps or the metal hook is connected to a force - measuring balance, which is driven by a small electric motor to increase the pulling force at a steady rate. When the tension reaches its limit, the balance shows the required maximum tension.
The maximum tension of the balance of the standard instrument is 5kg. When measuring carpets with greater tension, a balance with a capacity of 10kg can be selected.
Dimensions: W430 mm, D300mm, H535 mm
Power consumption: 20 W
Compliance Standards
BS 5229: 1975 (1996), ISO 4919: 1978
Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.