Femoral Stem Fatigue Performance Testing Machine
StandardASTM F2003 (Standard Test Method for Fatigue Testing of Orthopedic Implants)ISO 14879-1 (Tot
E-Mail-Adresse: info@standard-groups.com
Inhalt
Standard
- ASTM F2003 (Standard Test Method for Fatigue Testing of Orthopedic Implants)
- ISO 14879-1 (Total Hip Joint Prostheses - Fatigue Testing of Femoral Stems)
- FDA 21 CFR Part 820 (Quality System Regulation for Medical Devices)
Product Advantages
- Biomechanically Accurate Testing
- Multi-axis load application (axial, bending, torsion) replicates physiological gait cycles with ±1% force accuracy.
- High-Frequency Performance
- 50 Hz operation accelerates testing cycles, reducing time-to-market for new implant designs.
- Advanced Data Analytics
- AI-powered software predicts fatigue life (S-N curves) and identifies crack initiation points using real-time strain mapping.
- User-Centric Design
- 15.6-inch touchscreen interface with multilingual support (English, German, Chinese, Japanese) and one-touch test protocol selection.
- Regulatory Compliance
- Built-in audit trails, electronic signatures, and 21 CFR Part 11 compliance for seamless FDA/CE submissions.
Product Features
- Multi-Modal Testing:
- Axial Compression: 0–10 kN (±0.01 kN accuracy).
- Bending Moment: 0–50 Nm (±0.05 Nm accuracy).
- Torsional Load: ±180° rotation (0.01° resolution).
- Combined Loading: Programmable waveforms for simultaneous axial/bending/torsional stress.
- Environmental Control:
- Temperature-regulated bath (-20°C to +50°C) for simulating in-vivo conditions (e.g., cryogenic fatigue).
- Safety First:
- Overload protection, emergency stop, and laser-guided specimen alignment prevent sample damage and operator injury.
- Modular Expandability:
- Optional upgrades for high-temperature testing, corrosion simulation, and third-party software integration.
Technical Parameters
Parameter | Spezifikation |
---|
Axial Load Capacity | 0–10 kN (±0.01 kN accuracy) |
Bending Moment Capacity | 0–50 Nm (±0.05 Nm accuracy) |
Torsional Range | ±180° (0.01° resolution) |
Frequency Range | 0.1–50 Hz (adjustable) |
Temperature Control | -20°C to +50°C (±0.5°C accuracy) |
Data Acquisition Rate | 100,000 Hz (strain/load channels) |
Power Supply | 220V/110V AC, 50/60Hz, 2.5kW |
Dimensions (L×W×H) | 1.2×0.8×1.8 m |
Weight | 350 kg |
Operating Environment | 10–35°C, ≤70% RH (non-condensing) |
Accessories Included
- Specimen Clamps: Adjustable fixtures for femoral stems (Ø8–25mm).
- Calibration Kit: Load cell, torque sensor, and certification for annual validation.
- Safety Gear: Heat-resistant gloves, face shield, and emergency eyewash station.
- User Manual & Software: Digital guide (multilingual) + AI analytics platform for fatigue life prediction.
- Environmental Chamber: Temperature-controlled bath with antifreeze additive.
Ideal For:
- Orthopedic implant manufacturers (hip/knee prostheses)
- Medical device testing laboratories
- Regulatory certification bodies (FDA, CE, TÜV)
- Biomechanical research institutions
Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.