STD-TE 76 TWO STATION RECIPROCATING VACUUM TRIBOMETER - Qinsun
Professionelle Prüfgeräte Hersteller
Nationale Beratungshotline:+86 021-64208466
Produkte
Aktueller Standort:Home > Prüfgerät > Umweltprüfgeräte >

STD-TE 76 TWO STATION RECIPROCATING VACUUM TRIBOMETER

DescriptionThe TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, whi

WhatsApp: +86 13816217984

E-Mail :info@qinsun-lab.com

Inhalt

Beschreibung

The STD-TE 76 is a two-station, vertical axis, long stroke reciprocating tribometer, which combines the reciprocating drive mechanism and fixed specimen mounting from the TE 77 High Frequency Friction Machine with a UHV test chamber.

Technical Specifications

Contact Configurations:Point Contact

Line Contact

Area Contact
Load Range:5 to 500 N
Laboratory Chiller:-35°C to 150°C
Temperature Sensor:PT-100
Frequency Range:2 to 25 Hz
Stroke Range:See following tables
Friction Transducer:Piezo-Electric Type
Interface:Serial Link Interface Module
Software:COMPEND 2000
Motor:1.1 kW a.c. vector motor, 2048 ppr encoder



Stroke Range

Continuously Variable Cam – 0 to 12.5 mm

Angle – degrees:Minimum – mmMaximum – mm
002
181.043.04
362.654.65
544.256.25
725.757.75
907.099.09
1088.2410.24
1269.1711.17
1449.8511.85
16210.2612.26
18010.412.4



Step Variable 0 to 12.5 mm:

Angle – degrees:Nominal Stroke – mm
00
181.94
363.83
545.63
727.29
908.77
10810.03
12611.05
14411.79
16212.25
18012.5
Step Variable 12.5 to 25 mm:

Angle – degrees:Nominal Stroke – mm
012.5
1813.05
3614.26
5415.97
7217.89
9019.8
10821.54
12623
14424.09
16224.77
18025



Test Chamber

Pressure:Atmospheric to 100 Picobar (10-5 Pa)
Environment:Air, inert gas or vacuum
Material:304 stainless steel
Surface Treatment:Glass bead blasted
Viewports:Fused Silica
Electrical Feedthrough:1 kVolts , 15 Ampere
Coaxial Feedthrough:BNC through Flange
Thermocouple:Type K through Flange
Vacuum Transducer:Cold Cathode and Pirani



Laboratory Chiller

Fluid Temperature:-35°C to +150°C.



Automatically Controlled ParametersFrequency

Load

Temperature

Chamber Pressure

Test Duration



Manually Controlled ParameterStroke



Measured ParametersFriction

Load

Temperature

Chamber Pressure

Frequency

Friction Coefficient

.
Services

Electricity:220/240 V, single phase, 50/60 Hz, with neutral and earth, 4.5 kW
Clean, dry air:4 cfm at 8 bar (120 psi)


Haftungsausschluss: Die oben genannten Inhalte dienen ausschließlich zur Referenz und Kommunikation zwischen Brancheninsidern und garantieren ihre Genauigkeit oder Vollständigkeit nicht. Gemäß den einschlägigen Gesetzen und Vorschriften und den Vorschriften dieser Website sollten Einheiten oder Einzelpersonen, die verwandte Gegenstände kaufen, gültige Qualifikationen und Qualifikationsbedingungen erhalten.


Online-Nachricht

Kontaktdaten

Unternehmen Telefon

+86-21-6420 0566

Arbeitszeiten

Montag bis Freitag

Handy:

13816217984

Email:

info@qinsun-lab.com